Test Code LAB1111 von Willebrand Factor Multimer (vWF Multimer)
Performing Laboratory
BloodCenter of Wisconsin
Methodology
Electrophoresis
Specimen Requirements
Call Laboratory Medicine resident at digital pager 314-747-1320 for approval before drawing the specimen (with the exception of St. Louis Children’s Hospital patients).
Specimen must arrive within 4 hours of draw.
Specimen Type: Plasma
Container/Tube: Light-blue top (citrate)
Specimen Volume: 2 Full tubes
Specimen Minimum Volume: 0.5 mL
Collection Instructions:
1. Draw a discard tube prior to light-blue top (citrate)
tube.
2. Tube should remain stoppered. Allow tube to fill by vacuum
completely. Mix by gentle inversion.
3. Blood should not be drawn through an indwelling catheter or an
A-V shunt.
4. Clotted blood or an insufficient specimen is not acceptable.
5. Avoid hemolysis.
Additional Information: If possible, include result of von Willebrand factor antigen with specimen.
Day(s) Test Set Up
Varies
Turnaround Time:
STAT: not available
Routine: 7 to 10 days after receipt at reference laboratory
Test Classification and CPT Coding
85247
Reference Values
An interpretive report will be provided.
Specimen Transport Temperature
Ambient/Refrigerate NO/Frozen NO
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
4 hours at ambient temperature, unprocessed
Laboratory Processing Instructions:
BJH Core Laboratory will forward to the performing laboratory.
Centrifuge specimen for 15 minutes. Transfer top two thirds of plasma (minimum volume: 0.5 mL) into a labeled, plastic, screw-cap vial, and freeze. Send specimen frozen in dry ice to the BloodCenter of Wisconsin. Ship Monday through Thursday only.