Test Code LAB1113 Factor XIII, Qualitative, Plasma
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Methodology
Clot Solubility
Literature References:
Sirridge MS. Detection of Factor XIII activity. Lea & Febiger, 1974;150-1.
Specimen Requirements
Specimen Type: Plasma
Container/Tube: Light-blue top (citrate)
Specimen Volume: 1 Full tube
Specimen Minimum Volume: Full tube
Collection Instructions:
- Draw a discard blue top tube prior to drawing a light-blue top (citrated) tube if using a Winged Infusion Set. Discard tube should be under filled and discarded.
- Clotted blood or an insufficient specimen is not acceptable.
- Avoid phlebotomy techniques which cause hemolysis and heparin contamination.
- Follow nursing policy on volume of blood to discard prior to collecting blood from indwelling heparinized catheters.
Analyte Stability:
4 hours at 18° C to 24° C.
Platelet-free plasma can be frozen at -20 for transport on dry ice up to 72 hours
or stored 6 months at -70° C.
Additional Information: If the patient is a hospital patient and the hematocrit is >55%, call Barnes-Jewish Hematology Laboratory at 314-362-5203 for instructions.
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
STAT: not available
Routine: 36 Hours from receipt in laboratory (24 hours incubation required)
Test Classification and CPT Coding
85291
Reference Values
Normal
Literature References:
1. Duckert F, June E, Shmerling DH. A hitherto undescribed congenital hemorrhagic diathesis probably due to fibrin stabilizing factor deficiency. Thromb Diath Haemorrh 1960;5:179.
2. Finlayson JS. Crosslinking of fibrin. Sem Thromb Hemost 1974;1:33-62.
3. Sirridge MS. Detection of Factor XIII activity. Lea & Febiger, 1974;150-1.
Specimen Transport Temperature
Ambient Yes/Refrigerate NO/Frozen Yes
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
4 hours at 18° C to 24° C.
Platelet-free plasma can be frozen at -20 for transport on dry ice up to 72 hours
or stored 6 months at -70° C.
Laboratory Processing Instructions:
Test performed in BJH Core Lab.
LOINC Code Information
Name | LOINC Code |
Factor XIII, Qualitative, Plasma | 3241-7 |