Test Code LAB28650 Echinococcus Antibody, Serum
Performing Laboratory
Missouri Public Health Laboratories
Methodology
Enzyme Immunoassay (EIA)
Specimen Requirements
Specimen Type: Serum
Container/Tube: Plain red top
Specimen Volume: Full tube
Specimen Minimum Volume: 1.5 mL
Day(s) Test Set Up
Varies
Turnaround Time:
STAT: not available
Routine: approximately 4 weeks
Test Classification and CPT Coding
Not applicable
Reference Values
Significant titer: ≥1:32
Sensitivity at ≤1:128 is 91%
Specificity at ≥1:128 is 83%
Up to 50% of patients with hydatid cysts in the lung or calcified cysts are seronegative.
Specimen Transport Temperature
Ambient
Additional Information
For BJH Laboratory Use Only