Test Code LAB556 Aldolase, Plasma

Performing Laboratory

Barnes-Jewish Hospital Laboratory

Methodology

Enzymatic

Literature Reference:

Package insert: Aldolase reagent. Roche Corporation, 6/2015.

Specimen Requirements

Specimen must arrive, be processed, and separated from cells within 2 hours of draw.

 

Hospital Patient:

Specimen Type: Plasma

Container/Tube: Mint-green top (lithium heparin)

Specimen Volume: Full tube

 

Collection Instructions: Hemolyzed specimen is not acceptable.

 

Non Hospital Patient:

Call Barnes-Jewish Hospital Laboratory Customer Service at 314-362-1470 for STAT pick-up.

 

Specimen Type: Plasma or Serum

Container/Tube: Mint-green top (lithium heparin), Red top (plain no gel)

Specimen Volume: Full tube

Specimen must be processed, separated from cells, and aliquoted off of gel before tranport from outpatient or other HSO lab sites.

Day(s) Test Set Up

Monday through Sunday

Turnaround Time:
STAT: Not available 
Routine: 2 to 4 hours after receipt in laboratory

Test Classification and CPT Coding

82085

Reference Values

0-18 yrs: </= 14.7 Units/L

> 18 yrs: 0.1 - 8 Units/L

Literature Reference:

Rifai N, Horvath AR, Wittwer AT eds: Textbook of Clinical Chemistry and Molecular Diagnostics 6 th ed: Chapter 29, p. 424, Elsevier, St. Louis, MO 2018.

Specimen Transport Temperature

Ambient <2 hours/Refrigerate <2 hours OK

Additional Information

For BJH Laboratory Use Only
Alternate Tube:

1 dark green-top (lithium heparin) tube

1 red-top tube
1 lavender-top (EDTA) tube

Laboratory Processing Instructions:
Hemolyzed specimen is unacceptable.

Test performed in BJH Core Lab.  Processed by automated line for delivery to the Cobas 8000.  Completed specimens are stored refrigerated for 5 days.

Special Instructions

See Analyte Stability Chart under General Information for a complete list.

LOINC Code Information

Name LOINC Code
Aldolase 1761-6