Test Code LAB5704 Cardiolipin Antibody, IgG
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Methodology
Multiplex Flow Immunoassay
Literature Reference:
Package Insert: BioPlex 2200 APLS IgG kit. BioRad Laboratories, Inc. 10/2013
Specimen Requirements
Specimen Type: Serum
Container/Tube: Plain Red Top
Specimen Volume: Full tube
Test Classification and CPT Coding
86147
Reference Values
Cardiolipin A Antibiody |
Units | Interpretation |
< 20 GPL Units/mL | Negative | |
> 20 GPL Units/mL | Positive |
Interpretive data for IgG: Anticardiolipin antibodies are associated with certain clinical events including unexplained arterial and venous thromboemboli, and unexplained pregnancy morbidity. However, detection of low levels of anticardiolipin antibodies occurs in both healthy individuals and patients with co-morbidities not associated with the antiphospholipid antibody (APA) syndrome including inflammatory and infectious conditions. In order to improve specificity, the International Congress on Antiphospholipid Antibodies recommends ACL antibodies of IgG or IgM isotype present in medium or high titer (e.g. > 40 GPL, or >the 99th percentile), on two or more occasions, at least 12 weeks apart, to support a diagnosis of antiphospholipid syndrome. The cutoff for this assay was developed from data based on the 99th percentile. In addition, the International Congress on Antiphospholipid Antibodies does not recommend testing for IgA ACA. These results were obtained with the BioRad BioPlex 2200 System. Cardiolipin IgG values obtained with different manufacturers' assay methods may not be used interchangeably.
Reference Interval Literature References:
Miyakis S, Lockshin MD, Atsumi T, Branch DW, Brey RS et al. International consensus statement on and update of the classification criteria for definite antiphospholipid syndrome. J Thromb Heamost 2006; 4:295-306
Package Insert: BioPlex 2200 APLS IgG kit. BioRad Laboratories, Inc. 10/2013
Specimen Transport Temperature
Ambient
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
See Analyte Stability Chart
Laboratory Processing Instructions:
Test performed in BJH Core Lab. Processed by automated line and aliquot stored refrigerated for batch analysis. Completed specimens are stored refrigerated for 5 days.
Day(s) Test Set UP
Monday through Sunday
Cut-off time: 1000
Turnaround Time:
STAT: not available
Routine: results will be available the day of testing
LOINC Code Information
Name | LOINC Code |
Cardiolipin Antibody, IgA | 3181-5 |