Test Code LAB5774 Immunoglobulin Free Light Chains, Serum
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Methodology
Profile Information:
Includes kappa free light chain (FLC), lambda FLC, and kappa/lambda FLC ratio. Tests cannot be ordered separately.
Method Name:
Binding Site Optilite tubidimetric
Results from different manufacturers or methods may not be comparable. Serial testing should be performed using the same method.
Literature Reference:
Optilite Freelite Kappa Free Kit. Insert Code: INS018.OPT.A version 2nd. October 2018, The Binding Site Group Ltd. 8 Calthrope Road, Edgbaston, Birmingham, B15 1QT, UK
Specimen Requirements
Specimen Type: Serum
Container/Tube: Plain red top
Specimen Volume: Full tube
Day(s) Test Set Up
Monday through Friday
Cut-off time: 1000
Turnaround Time:
STAT: not available
Routine: results available by 1500 the day of testing
Test Classification and CPT Coding
Test Classification:
This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer’s instructions.
CPT Code:
83521 x 2
Reference Values
KAPPA-FREE LIGHT CHAIN
0.33-1.94 mg/dL
LAMBDA-FREE LIGHT CHAIN
0.57-2.63 mg/dL
KAPPA/LAMBDA FLC RATIO
0.26-1.65
Literature Reference:
Katzmann JA, Clark RJ, Abraham RS, et al. Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains. Clin Chem 2002;48:1437-44.
Specimen Transport Temperature
Ambient
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
Store specimen at 2° C to 8° C for up to 4 weeks. For prolonged storage, freeze at ≤-20° C. Repeated freeze/thaw cycles should be avoided.
Laboratory Processing Instructions:
Test performed in BJH Core lab. Processed by automated line and aliquot stored refrigerated for batch analysis. Completed specimens are stored refrigerated for 5 days.
LOINC Code Information
Name | LOINC Code |
Kappa/Lambda Free Light Chain Ratio |
40844-3 |