Test Code LAB758 Factor X, Plasma
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Methodology
Absorbance measurement, Clot signature formation
Literature References:
HemosIL RecombiPlasTin 2G (0020003050) package insert issued 09/2016, Instrumentation Laboratory.
Specimen Requirements
Specimen Type: Plasma
Container/Tube: Light-blue top (citrate)
Specimen Volume: Full tube
Specimen Minimum Volume: Full tube
Collection Instructions:
- Draw a discard blue top tube prior to drawing a light-blue top (citrated) tube if using a Winged Infusion Set. Discard tube should be under filled and discarded.
- Clotted blood or an insufficient specimen is not acceptable.
- Avoid phlebotomy techniques which cause hemolysis and heparin contamination.
- Follow nursing policy on volume of blood to discard prior to collecting blood from indwelling heparinized catheters.
Analyte Stability:
4 hours at 18° C to 24° C.
Platelet-free plasma can be frozen at -20 for transport on dry ice up to 72 hours
or stored 6 months at -70° C.
Additional Information: If the patient is a hospital patient and the hematocrit is >55%, call Barnes-Jewish Hematology Laboratory at 314-362-5203 for instructions.
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
STAT: 2 hours after receipt in laboratory
Routine: 2-4 hours after receipt in the laboratory
Test Classification and CPT Coding
85260
Reference Values
60%-160%
Literature References:
1. Colman RW, Hirsch J, Marder VJ, Salzman EW. Hemostasis and thrombosis, basic principles and clinical practice. Philadelphia: J.B. Lippincott Co., 1982.
2. Thompson AR, Harke LA. Manual of hemostasis and thrombosis, Edition 3. Philadelphia: F.A. Davis Co., 1983.
Specimen Transport Temperature
Ambient Yes/Refrigerate NO/Frozen Yes
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
4 hours at 18° C to 24° C.
Platelet-free plasma can be frozen at -20 for transport on dry ice up to 72 hours
or stored 6 months at -70° C.
Laboratory Processing Instructions:
Test performed in BJH Core Lab.
LOINC Code Information
Name | LOINC Code |
Factor X, Plasma | 3217-7 |