Test Code LAB85 Gamma Glutamyltransferase (GGT), Plasma
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Methodology
Enzymatic
Literature Reference:
Package insert: Gamma-glutamyltransferase GGT-2 liquid reagent. Roche Corporation, 01/2022.
Specimen Requirements
Specimen Type: Plasma
Container/Tube: Mint-green top (lithium heparin)
Specimen Volume: Full tube
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
STAT: 1 hour after receipt in laboratory
Routine: 2 to 4 hours after receipt in laboratory
Test Classification and CPT Coding
82977
Reference Values
Males
0 - 3 months: 20-200 Units/L
> 3 months - 1 year: 5-115 Units/L
> 1 year - 12 years: 5-35 Units/L
> 12 years: 10-50 Units/L
Females
0 - 3 months: 20-200 Units/L
> 3 months - 1 year: 5-115 Units/L
> 1 year - 12 years: 5-35 Units/L
> 12 years: 5-35 Units/L
Unknown
0 - 3 months: 20-200 Units/L
> 3 months - 1 year: 5-115 Units/L
> 1 year - 12 years: 5-35 Units/L
> 12 years: 10-35 Units/L
Literature References:
1. Szasz G, et al: Clin Chem. 15, 124, 1969.
2. Rifai N, Horvath AR, Wittwer AT eds: Textbook of Clinical Chemistry and Molecular Diagnostics 6th ed: Chapter 61, p. 1348, Elsevier, St. Louis, MO 2018.
.
Specimen Transport Temperature
Ambient
Additional Information
For BJH Laboratory Use Only
Alternate Tube:
1 dark green-top (lithium heparin) tube
1 lavender-top (EDTA) tube
1 red-top tube
Laboratory Processing Instructions:
Test performed in BJH Core Lab. Processed by automated line for delivery to the Cobas 8000. Completed specimens are stored refrigerated for 5 days.
Test performed in Ambulatory Cancer Building Lab. Centrifuge sample and deliver to the Cobas. Completed specimens are stored refrigerated for 5 days.
Special Instructions
See Analyte Stability Chart under General Information for a complete list.
LOINC Code Information
Name | LOINC Code |
Gamma glutamyl transferase | 2324-2 |