Sign in →

Test Code Lab1268 Trichinella Antibody, Serum

Performing Laboratory

Centers for Disease Control

Methodology

Agglutination

Specimen Requirements

Specimen Type: Serum

Container/Tube: Plain red top

Specimen Volume: Full tube

Specimen Minimum Volume: 2 mL

Forms: Centers for Disease Patient History Form in Special Instructions.

Day(s) Test Set Up

Varies

Turnaround Time:
STAT: not available
Routine: approximately 4 weeks 

Test Classification and CPT Coding

Not applicable

Reference Values

No antibody detected
Positive titers should be considered diagnostic of Trichinella infection. False-negative results may occur in lightly infected individuals or within the first 3 to 4 weeks of illness in moderately infected patients. A second specimen drawn 2 to 4 weeks after the first might prove more informative in those serologically-negative patients with clinical symptoms of trichinosis.

Specimen Transport Temperature

Ambient

Additional Information

For BJH Laboratory Use Only

Laboratory Processing Instructions:

BJH Core Lab will forward to the performing laboratory. Centrifuge specimen. Transfer an aliquot of serum into plastic vial. Send in round mailers via courier to SLCH laboratory where they will be picked up by the Missouri State Public Health Laboratory.